1. Check the capacity of the system you wish to replace 2. Select from the Panasonic range the best system to replace it with 3. Follow the procedure detailed in the brochure and technical data Simple Reuse of existing piping (Renewal Design & Installation) Notes on Reuse of Existing Refrigerant Piping
I use to have a pdf for easy reference that I cannot find right now but; E9JKR = 1/4-3/8 inch. E12JKR-E21JKR = 1/4-1/2 inch. E24JKR-E28JKR = 1/5-5/8 inch. W7DKR-W9DKR = 1/4-3/8 inch. W12EKR-W18DKR = 1/4-1/2 inch. W24EKR = 1/4-5/8 inch. All ducted up to 14kW = 3/8-5/8 inch.
Specifications See all 1)The sound pressure of the indoor unit shows the value measured of a position 1m in front of the main body and 0,8m below the unit. The sound pressure is measured in accordance with JISC9612.
Features: Includes Nanoe X air purification technology. Outstanding operating range. Cold draft reduction technology. 16kW Cooling - 18kW Heating Capacity. Panasonic High Static Ducted System 16kW. Indoor: S-160PE3R. Outdoor: U-160PZH2R5 | Single Phase R32. Includes CZ-RTC5B Wired Controller. 1. Gravure size The copper pipe for this air conditioner mainly uses 2 types: For 1 HP machines (~ 9000 BTU), use copper pipes with an outer diameter of 10 mm. For 1.5 HP machines (~ 12000 BTU), use copper pipes with an outer diameter of 10 mm or 12 mm. For 2 HP machines (~ 18000 BTU), use copper pipes with an outer diameter of 12 mm.

CS/CU-Z35XKR Panasonic 3.5kW Deluxe Z Reverse Cycle Split System Air Conditioner R32 | Advance Air Purification System | Nanoe™X. Skip to Home Split System Air Conditioners Panasonic Split System Air Conditioners Panasonic CS/CU-Z35XKR 3.5kW Z Series Reverse Refrigeration Pipe Diameter: Liquid Size: ø 6.35 (1/4) ø 9.52 (3/8) Gas

What are the pipe sizes? Asked by james on 06/26/2012 1 Answer. ManualsOnline posted an answer 11 years, 5 months ago. The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here. Allowable piping length and difference in height are the maximum piping distance (or height) between the indoor unit and outdoor unit at which installation is possible. Allowable piping length and difference in height vary by model. Case studies What's happening Models 3.6 kW KIT-36PY3ZH5 (S-36PY3E + U-36PZH3E5) 5.0 kW KIT-50PY3ZH5 (S-50PY3E + U-50PZH3E5) 6.0 kW KIT-60PY3ZH5 (S-60PY3E + U-60PZH3E5) 4 way 60x60 cassette - PY3 From 3,6 to 6,0 kW (3 capacity sizes). Chassis dimensions (H x W x D): 243 x 575 x 575 mm. SEER/SCOP class A++*. Built-in drain pump. .